The Main-Index page provides links to woven wire cloth and woven wire mesh information. Our Products include Woven Wire Cloth Wire Mesh, Micronic Filter Cloth, Square Mesh Market Grade and Mill Grade, Stainless Steel Bolting Cloth and Heavy-Duty Industrial Sand & Gravel Screens. Illustrations of the most popular wire cloth Weave Styles Wire Cloth Reference Section provides technical information. Send Mail to the WIRE CLOTH PEOPLE.

Micronic Filter Cloth

Particle Retention and Flow Rate Data

 

Plain Dutch Weave Filter Cloth

Particle Retention

Thickness

Weight

Flow Rate Per Square Inch

 Microns

Inches

Inches

lbs./sq.ft.

Oil GPM

Fuel GPM

Air SCFM

325

0.0128

0.059

1.03

3.8

8.5

47

295

0.0116

0.048

0.76

3.7

8.3

45

245

0.0096

0.037

0.69

3.6

8.3

44

138

0.0054

0.03

0.52

3.5

7.9

43

102

0.0042

0.021

0.37

3

7.3

38

84

0.0033

0.016

0.27

2.5

7.2

35

82

0.0032

0.02

0.38

1.6

4.5

27

64

0.0025

0.012

0.22

1.9

6.2

33

62

0.0024

0.016

0.28

1.3

4.4

26

49

0.0019

0.013

0.23

1

4.2

24

 

Twilled Dutch Weave Filter Cloth

Particle Retention

Thickness

Weight

Flow Rate Per Square Inch

 Microns

Inches

Inches

lbs./sq.ft.

Oil GPM

Fuel GPM

Air SCFM

98

0.0039

0.035

0.85

1.12

4.1

19

90

0.0035

0.027

0.56

1.20

4.2

21

74

0.0029

0.028

0.61

1.05

3.1

17

69

0.0027

0.028

0.64

0.90

3.0

16

46

0.0018

0.022

0.59

0.45

2.6

14

41

0.0016

0.012

0.26

0.63

4.1

21

36

0.0014

0.014

0.36

0.24

2.1

12

32

0.0013

0.011

0.25

0.31

2.4

14

17

0.0007

0.006

0.16

0.12

1.89

11

10

0.0004

0.006

0.16

0.10

1.66

9.2

5

0.0002

0.003

0.10

0.06

1.12

7.8

 

Twilled Square Weave Filter Cloth

Particle Retention

Thickness

Weight

Flow Rate Per Square Inch

 Microns

Inches

Inches

lbs./sq.ft.

Oil GPM

Fuel GPM

Air SCFM

145

0.0057

0.033

0.53

4.7

10.1

50

141

0.0055

0.018

0.28

7.2

12.3

84

 

Micron Rating:
This data was determined using the "bubble point" test method.                          One micron equals 0.00003937" or 0.001mm.
Flow Rate Data:
This data was based on a test sample one square inch in area.
Oil   - MIL-H-5606-B @ 80°F (viscosity 90 SSU) at 1 psid.
Fuel - MIL-F-7024-A, Type II @ 78°F (viscosity 35 SSU) at 1 psid.
Air   - Tested @ 75°F at 1 psid.
 

[Main Wire Cloth]  [Wire Mesh Products]   [Weaving Materials]  [Screen Reference]

 

Telephone: 1+ (360) 835-7507

Copyright © 1999  Woven Wire Cloth Division, Screen Technology Group, Inc.

Last modified: March 07, 2006